| Freezer Model No.1 |
| 410 | 415 | 420 | 520 | 525 | 530 |
Enclosure Length | 15'-8" | 20'-8" | 25'-8" | 25'-8" | 30'-8" | 35'-8" |
| 4.8m | 6.3m | 7.8m | 7.8m | 9.4m | 10.9m |
Enclosure Width5 | 11'-2" | 11'-2" | 11'-2" | 12'-8" | 12'-8" | 12'-8" |
| 3.4m | 3.4m | 3.4m | 3.9m | 3.9m | 3.9m |
Enclosure Height2 | 15'-0" | 15'-0" | 15'-0" | 15'-0" | 15'-0" | 15'-0" |
| 4.6m | 4.6m | 4.6m | 4.6m | 4.6m | 4.6m |
Freezer Fans3 (No x hp) | 2x10hp | 3x10hp | 4x10hp | 4x15hp | 5x15hp | 6x15hp |
Belt Drives4 (No x hp) | 2x ½hp | 2x ½hp | 2x ¾hp | 2x ¾hp | 2x 1hp | 2x 1hp |
Max Defrost Water Req'd. | 105 gpm | 150 gpm | 210 gpm | 210 gpm | 255 gpm | 300 gpm |
| 397 lpm | 568 lpm | 795 lpm | 795 lpm | 965 lpm | 1135 lpm |
Belt Washer Water Req'd | 13 gpm | 13 gpm | 13 gpm | 16 gpm | 16 gpm | 16 gpm |
| 49 lpm | 49 lpm | 49 lpm | 60 lpm | 60 lpm | 60 lpm |
- First digit is belt width (in feet) and last two digits are effective length (in feet).
- Export models have their height reduced by 18" [46cm].
- Supplied motors are for 480V/3/60 Hz. Export models are de-rated for 380V/3/50 Hz. and are supplied with supplied with 15hp and 20hp motors.
- Belt drives are A/C electric and can be supplied with hydraulic drive, pump and reservoir package.
- For Side-Coil Models the enclosure width is increased by 5'-0"
(Subject to change without notice)
Product In @ 68°F [20°C] Out @ 0°F [-18°C] | Freezer Model No.1 |
|---|
| 410 | 415 | 420 | 520 | 525 | 530 |
Peas Lima Beans Cut Corn | lb/hr kg/hr | 2,200 | 3,300 | 4,400 | 6,000 | 8,000 | 10,000 |
| 999 | 1,498 | 1,998 | 2,724 | 3,632 | 4,540 |
| TR2 | 41 | 60 | 78 | 105 | 135 | 165 |
Cut Beans Blueberries Pea Pods | lb/hr kg/hr | 2,200 | 3,300 | 4,400 | 6,000 | 8,000 | 10,000 |
| 999 | 1,498 | 1,998 | 2,724 | 3,632 | 4,540 |
| TR2 | 46 | 69 | 89 | 120 | 155 | 190 |
Diced Potatoes Diced Carrots Mushrooms | lb/hr kg/hr | 2,000 | 3,000 | 4,000 | 5,400 | 7,000 | 8,000 |
| 908 | 1,362 | 1,816 | 2,452 | 3,178 | 3,632 |
| TR2 | 43 | 64 | 83 | 111 | 142 | 175 |
Cut Broccoli Strawberries Brussel Sprouts | lb/hr kg/hr | 1,500 | 2,400 | 3,200 | 4,500 | 6,200 | 7,700 |
| 681 | 1,090 | 1,453 | 2,043 | 2,815 | 3,496 |
| TR3 | 37 | 55 | 70 | 97 | 127 | 155 |
Cob Corn Baby Carrots Cauliflower Florets | lb/hr kg/hr | 1,500 | 2,100 | 2,800 | 4,200 | 5,400 | 7,000 |
| 681 | 953 | 1,271 | 1,907 | 2,452 | 3,178 |
| TR3 | 35 | 48 | 62 | 90 | 115 | 145 |
- First digit is belt width (in feet) and last two digits
are effective length (in feet).
- Required refrigeration tons at -26°F [-32.2°C]
- Required refrigeration tons at -35°F [-37.2°C]
Subject to change without notice. Contact Mechanical Refrigeration, Inc. for
additional capacities and products.
|